Technical Support

Need help?

 

Error 2055 installing the protection or the Endpoint Protection agent

Information applies to:

Products
Endpoint Protection
Endpoint Protection Plus

Symptoms

On installing the protection or the Endpoint Protection communications agent error 2055 occurs.

Cause

The WalUpg.ini configuration file is incomplete. The URL_WEB_GUID entry in the GENERAL section of file %ProgramFiles%\Panda Security\WaAgent\WalUpg\WALUpg.ini cannot be read.

Elements to check

Check whether the WALUpg.ini configuration file exists in the relevant folder. To do this, follow the steps below:

  1. Go to %ProgramFiles%\Panda Security\WaAgent\WalUpg
  2. Make sure the WALUpg.ini file exists in that directory.
  3. Open the WALUpg.ini file and check it includes an entry similar to

    http://enterprise.updates.pandasoftware.com/updates_ent/lastupgrade_default_XX_X_XX.html
Solution

Copy the WALUpg.ini file from another computer to the directory %ProgramFiles%\Panda Security\WaAgent\WalUpg of the affected computer.

If the incident persists, proceed as follows:

  1. Uninstall the agent using the Add or Remove Programs option.
    NOTE: You don’t need to uninstall the protection.
  2. Download and run the installer again from the Endpoint Protection console.
  3. The program will be installed and will detect if the protection is installed or not or whether it needs updating.

Data needed to report the incident

If the issue is not solved, it is then necessary to collect a series of data from the computer. Please, read How to report problems from the Endpoint Protection console and follow the instructions indicated.

Help nº- 20140519 502055 EN