您的位置: Panda Security > IT Security for Business > support > Soporte Productos Panda Security

您需要什么样的帮助?
(例如::Panda AdminSecure 1093 error)
Print

Error 3372 updating the Panda Cloud Office Protection signature file

Information applies to:

Products
Panda Cloud Office Protection
Panda Cloud Office Protection Advanced

Symptom

On updating the Panda Cloud Office Protection signature file, error 3372 occurs.

Causes

This error is due to a lack of sufficient space to download and save the signature file to disk. The space required is the total amount occupied by the compressed file downloaded plus the extracted file.

Data needed to report the incident

If the issue is not solved, it is necessary to collect a series of data from the computer. This information is collected automatically by the PSInfo tool that you need to download and run following these instructions:

  1. From a computer with Internet connection, download the PSInfo2_V2.exe file into your computer and save it in your Windows Desktop.
  2. Double click the PSInfo2_V2.exe file, so that the information about hardware and software from your computer is gathered.
  3. Fill in all the requested fields.
  4. If PCOP is installed in the computer, the PCOPDIAGS application will be launched.
  5. Follow the PCOPDIAGS wizard.
  6. When the data collection finishes, a file called XXXX.psz is generated in your hard drive. Send to Panda Security this file which is located in the TEMP folder of your hard drive, by default.

In the event that for whatever reason PSInfo cannot be run, or the PCOPDIAGS application has not been released it is necessary to send Panda the following data:

  1. In the %programfiles%\Panda Security\WaAgent\WalUpd\Data\Files folder, locate the downloaded file xxxxxxxx_pav.rar and decompress it.
  2. Note down the error displayed when manually decompressing the file and report it to Panda.
  3. WalUpd log file (once the error occurs). To get it, follow the steps below:
    1. Find the WalUpd.ini file in %Programfiles%\Panda Security\WaAgent\WalUpd
    2. Edit the file and add the following lines:

      [LOG]
      LevelLog=2000
    3. Restart the Panda Endpoint Administration Agent service.

      To reproduce the error, execute the local process. To do this:
      1. Go to the %ProgramFiles%\Panda Security\WaAgent\WasLpMng folder from a DOS window.
      2. Run the command waplpmng walupd –force

        The file, WALUPD.log, is saved in the folder %Programfiles%\Panda Security\WaAgent\WalUpd

Send the collected data to the Panda Security Tech Support address for analysis.

Help nº- 20130107 503372 EN
survey

让我们知道您的意见,以帮助我们改进我们的服务

您的建议将有助于更快速和有效地解决您的问题.

您是否在文中找到了解决方案? 谢谢你的答案

这篇文章应如何进行改善

你是否希望如何联系技术支持人员?