Print

How to reset the Panda Cloud Systems Management agent ID in cloned machines

Information applies to:

Products
Panda Cloud Systems Management

Situation

Companies tend to use system cloning: that is, they create an image of the system and install it on X computers.

A unique agent identifier (ID) is generated every time PCSM is installed. So, if an image of a system with PCSM installed is created, the image will also include the agent identifier.

Thus, if systems are cloned using that image, only one device will be shown on the console as all of them will have the same agent ID.

Resolution

In order to reset the PCSM agent ID in a cloned computer, proceed as follows:

  1. Install the agent (downloaded from the console using the desired profile), if it’s not previously installed. The machine must be connected to the internet to get installed.
  2. After the machine is shown in the console, disconnect the machine from the network or the Internet.
  3. In the local machine, remove the registry key HKLM\SOFTWARE\CentraStage. Remove this entire key along with anything that is inside it. This way the first time the Panda Cloud Systems Management agent connects to the Internet, it will find that no key is present and generate a fresh new device ID ensuring that all of your devices report back uniquely.
  4. Install the uVNC driver uVNCMirrorDriver.exe. This will ensure that you get the best possible performance when using VNC remote takeover sessions.

These steps will ensure that the cloned computer has a unique ID.